WattHour Sensors

Connects to the XR440 Data Logger using a PM-1 Pulse Module; no external power required. Connects directly to the XR5 Data Logger

Split core construction simplifies installation. No exposed metal parts.


WH-100-230 WattHour Sensor (0-100 Amps, 230 VAC)

Specifications - PACE WattHour Sensors
Input Current Single phase AC, 48 - 62 Hz, 0 - 125% rated current, load power factor: any.
Accuracy ±1.0% of full scale.
Power requirement Self powered
Operating Temperature -20 to 70°C (-4 to 158°F)
Pulse Output 10 WattHours per pulse
Contact Rating Form A, 30V peak, 100ma max.
Input Voltage ±10% rated voltage
Isolation Current/Voltage/Output: 2250 Vac
Voltage Sensing Lead Wires 5 ft twisted Black / White
Pulse Output Connection Detachable Screw Terminal Block
Maximum Conductor Size 1.0" diameter
Overall size 4.25" width x 3.5" height x 1.2" thick

 

Pace Part No.

AC Current

AC Voltage (Range)

Domestic (USA) Price

WH-100-115 0-100 Amps 115 (101 - 129)

$310.

WH-200-115 0-200 Amps 115 (101 - 129)

$310.

WH-100-230 0-100 Amps 230 (187 - 253)

$310.

WH-200-230 0-200 Amps 230 (187 - 253)

$310.

WH-100-277 0-100 Amps 277 (244 - 310)

$310.

WH-200-277 0-200 Amps 277 (244 - 310)

$310.

PM-1 Pulse Module; (required for any Watt Hour Sensor used with the XR440).

XR440 Data Logger, Description and Pricing

Catalog and Price List PDF: 2 MB / 15 pages

XR5 Data Logger

Placing an Order

Equivalent Pace model number reference
Current Previous (before 2007)
WH-100-115 WH-1100
WH-200-115 WH-1200
WH-100-230 WH-2100
WH-200-230 WH-2200
WH-100-277 WH-3100
WH-200-277 WH-3200