Pace Scientific Data Loggers and Sensors

[ Home | What's New | Products | Contact | International Distributors ]

Soil Moisture Sensors

Connect directly to any XR440 Data Logger input channel.  No external power required.


EC20 Soil Moisture Sensor

Specifications - PACE Soil Moisture Sensors
Accuracy ±3% typical

±1% with soil specific calibration

Measuring range 0 to saturation (saturated volumetric water content)
Operating temperature range 0 to 50°C (32 to 122°F)
Power requirements 7 ma (5 vdc) supplied by XR440
Cable 16 FT (5 meter)

 

Part No.

Overall Length Moisture sensing length

Maximum number that can be used with one XR440

Domestic (USA) Price

EC10 5.7 in. (145 mm) 3.9 in (100 mm) 2

105.

EC20 10 in. (254 mm) 7.8 in (200 mm) 2

105.

Installation and Setup Manual

XR440 Data Logger, Description and Pricing

Catalog and Price List PDF: 2 MB / 15 pages

Placing an Order

Tel: (704) 799-0688 / Fax: (704) 799-0177 / e-mail: sales@pace-sci.com

[ Home | What's New | Products | Contact | International Distributors ]

Copyright © 1999 Pace Scientific Inc.