Products

XR5 Data Loggers have eight "universal" analog inputs and three pulse inputs.  All XR5 sensors (below) require no external power.  Sensors can be mixed and matched in any combination, except a maximum of three DC Current Sensors or a maximum of six P1510-25 Pressure Sensors, due to the higher power requirements of these sensors.

XR5 Sensors

Temperature Probes
Precision thermistors with ±0.1 deg. C interchangeability, uses one analog input per probe.
 
RTD Temperature Sensors
For continuous temperatures up to 500°F (260°C), uses one analog input per sensor.
 
Relative Humidity
TRH-160 Temperature / RH Probe Combination Temperature and Relative Humidity Probe, uses two analog inputs per probe.
 
Pressure
Stainless Steel Pressure Sensors  Stainless Steel.  Pressure ranges from 0-25 to 0-20,000 psig; plus compound pressure ranges of Vac-150 and Vac-300 psig.
Low Pressure Sensors  For dry air and inert gases. Plastic Case. Pressure ranges from ±0.4 Inch H2O to 0-30 psi; Gauge, Differential, Barometric and Absolute models.  For dry air and inert gases.
Each Pressure Sensor uses one analog input
 
AC Current Sensors
High accuracy, split core, 0-100 amp to 0-1500 amp ranges, uses one analog input per sensor.
 
DC Current Sensors
0-50 amp and 0-100 amp ranges, uses one analog input per sensor.
 
AC Voltage Sensors
High accuracy, 0-300 Vac and 0-600 Vac models; uses one analog input per sensor.
WattHour Sensors
Split-core construction, 1% accuracy; uses one pulse input per sensor.
 
Light Sensor
General purpose, wide dynamic range; uses one analog input per sensor.
 
Solar Radiation Sensor
For environmental, agricultural, botanical and solar energy applications; uses one analog input per sensor.
Soil Moisture Sensors
For environmental, agricultural, and botanical applications; uses one analog input per sensor.
 
Rainfall Sensor
Tipping bucket design, 0.01" or 0.2 mm rainfall increments; uses one pulse input per sensor.
Wind Speed and Direction Sensor
Uses one pulse input (wind speed) and one analog input (wind direction) per sensor.
 
XR5 Weatherproof Cases
 
EC45 Compact Weatherproof Case
EC55 Weatherproof Case
 

User's Guide and Price List

  XR5-SE User's Guide and Price List  


Telephone
(704) 799-0688
FAX
(704) 799-0177
 
E mail
Sales: sales@pace-sci.com
Support: support@pace-sci.com
 
Address
Pace Scientific Inc., PO Box 4418, Mooresville, NC 28117

 


[ Home | What's New | Products | Contact | International Distributors ]

Copyright © 2005 Pace Scientific Inc.
Last modified: September 09, 2008